Agilent Micro GC User Information - Free ebook download as PDF File (.pdf), Text File. Agilent 3000 Micro Gas Chromatograph User Information. Warnings in the manual or on the instrument must be observed during all.
Think there’s no more room for GC innovation?
Think again
Think again
New Intuvo column chemistries: Extend the range of applications you can perform with the Intuvo 9000.
Agilent Intuvo 9000 GC system --
Innovation that drives greater business certainty
Labs have been facing the same challenges for years. Unplanned downtime, time-intensive tasks, and user technical limitations all impact a lab’s ability to deliver data fast—and deliver more to your bottom line.
Intuvo is Agilent’s answer to these challenges. Comprising a fully integrated solution of instrument, consumables, software, and services, Intuvo introduced enabling technologies you simply won’t find anywhere else.
Direct heating, shorter cycle times—planar column design
Why wait for columns to heat up and cool down?
Classic conventional ovens used in most GC systems first heat the air inside the oven, and then transfer the heat to the GC column. Effective… but not efficient.
Intuvo uses direct heating technology—a faster way to do GC. The planar column design enables efficient direct contact conduction heating, eliminating the need for large conventional ovens. Now you can run your methods in less time, in half the space, and using only a fraction of the power.
Go to: Intuvo columns
Fast, confident column changes—click-and-run, ferrule-free connections
Never fuss with ferrules again
Tired of chasing dropped ferrules? Intuvo uses ferrule-free face seals for all fittings within the gas flow path—making it easy to maintain flow path integrity.
What’s more, Intuvo takes the guesswork out of creating leak-free fittings. With just an audible ‘click’, you can create a leak-free seal in under one minute.
Go to: Intuvo supplies
An end to column trimming—Guard Chip technology
Protect, don’t repair
Disposable, easy-to-install Guard Chips provide almost a meter of sample flow path just before the Intuvo GC column. So column trimming—and peak shifting—become a thing of the past.
Imagine, a 15-meter column that will always be a 15-meter column!
Go to: Intuvo supplies
Improved Inert Flowpath—higher sensitivity, accuracy and reproducibility
Never repeat an analysis again
Flow path inertness is critical for accurate and reproducible analysis of trace levels of active analytes.
The Intuvo Inert Flow Path components provide reliable, consistent inertness that spans the entire flow path.
Go to: Intuvo supplies
New compact column design—same robust performance
Easily transfer your existing methods
Intuvo no-trim columns use the same dimensions and materials as existing Agilent GC columns. Their compact, planar design accommodates your existing capillary GC applications with speed and efficiency.
These columns also work hand-in-hand with Guard Chip technology to ensure separation consistency.
Go to: Intuvo columns
See how Intuvo can transform your lab.
New videos
Intuvo overview
Get an up-close look at the innovations that can make you—and your lab—more efficient.
Column changes made simple
Find out how to overcome this frustrating obstacle to your productivity.
Getting comfortable with consumables
Discover the many similarities between Intuvo and 7890B GC columns.
Increase lab productivity through efficient gas chromatography
See how Intuvo can drive incremental economic value with our new white paper.*
* White paper intended for illustration purposes only, and does not comprise a guarantee.
Return on investment.
Return on innovation.
See how Agilent’s Intuvo GC system delivers unexpected payoffs on your ROI.
Intuvo application resources
Solutions Page
Application notes:
Solutions Page
Application notes:
Solutions Page
Application notes:
Solutions Page
Application notes:
Solutions Page
Application notes:
Intuvo columns and supplies
Easily transfer your existing GC methods: Despite their compact, planar design that facilitates heating and cooling, Intuvo columns are identical in dimensions, construction materials, and separation phase to Agilent GC capillary columns. What’s more, a range of innovative, specially designed supplies makes Intuvo the most efficient, cost-effective, premium GC to own and operate.
![Download Agilent 3000 Micro Gc Manual Free Download Agilent 3000 Micro Gc Manual Free](https://img.yumpu.com/10258075/1/190x245/5973network-msd-specifications-5968-7358e.jpg?quality=85)
Serving your entire analytical lab
Industry-leading partnership platforms uniquely position Agilent to anticipate—and respond quickly—to your needs.
OpenLAB CDS
OpenLAB CDS incorporates the user interface standards of today’s software to establish an immediate sense of familiarity and confidence. Need optimum control of your Agilent instruments? OpenLAB CDS lets you to take full advantage of the advanced features built in to our state-of-the-art chromatographs.
This is how you GC
Our family of GC systems redraw the boundaries of performance and usability. High performance GC/MS instruments expand your lab in multiple dimensions with innovative technologies like the high efficiency JetClean self-cleaning ion source and dynamic MRM.
CrossLab Migration Services
Let us take the headache out of upgrading your laboratory. Agilent CrossLab Migration Services make it fast, easy, and cost effective to move up to new instruments and software, so that your lab can benefit from productivity-boosting innovations—with minimal workflow disruption.
Complete the form below to download our Return on Innovation information kit, which includes brochure, flyer, and poster.
2000-16. The Agilent Human 1 cDNA microarray.
Download JPEG (408 KB)
2000-15. Agilent ChemStation Plus Networked Data System.
Download JPEG (229 KB)
2000-14. Agilent's fully automated DNA microarray scanner.
Download JPEG (575 KB)
2000-13. The Agilent Cerity Networked Data System for Pharmaceutical QA/QC.
Download JPEG (741 KB)
2000-12. Agilent Technologies’ latest edition of Separation Times magazine spotlights how to improve detector performance.
Download JPEG (400 KB)
2000-11. Agilent's new 3000 Micro GC enables fast on-site analysis of virtually any type of complex gas and can run up to four channels simultaneously.
Download JPEG (400 KB)
2000-10. Agilent's new brochure titled 'Go Further, Faster: Accelerating the Efficiency of Fuel Cell Development,' publication number 5988-4397EN.
Download JPEG (920 KB)
2000-09. Agilent's latest edition of 'Separation Times' magazine reveals ways to increase GC productivity.
Download JPEG (1.5 MB)
2000-08. Rheodyne manual sample injection valves.
Download JPEG (787 KB)
Download TIFF (3.0 MB)
2000-07. The Agilent 3000A Micro GC Natural Gas Analyzer Brochure.
Download JPEG (598 KB)
2000-06. The Agilent 7500 Series ICP-MS.
Download JPEG (471 KB)
2000-05. The Agilent 3000A Micro GC.
Download JPEG (640 KB)
2000-04. The Agilent 3000 Natural Gas Analyzer.
Download JPEG (615 KB)
2000-03. The Agilent Crimper/decapper.
Download JPEG (27 KB)
2000-02. The Agilent 3000A Micro GC Brochure.
Download JPEG (359 KB)
2000-01. Agilent 1100 Series Micro Well-plate Autosampler.
Download JPEG (1156 KB)